Parameters | Units | Rating | |||||||
---|---|---|---|---|---|---|---|---|---|
Model | ASPIRO | 1KVA | 1KVA | 2KVA | 3KVA/5KVA | 5KVA/7.5KVA | 7.5KVA/10KVA | 10KVA | 15KVA |
Operating DC Voltage | Volts | 12 | 24 | 24 | 48 | 96 | 120 | 180 | 240 |
SPV Open Circuit Voltage Range (Min-Max) | Volts | 18-45 | 36-90 | 36-90 | 72-180 | 144-360 | 180-450 | 270-450 | 360-600 |
---|---|---|---|---|---|---|---|---|---|
Compatible SPV Panels | Volts | 12 | 24 | 24 | 48 | 96 | 120 | 180 | 240 |
MAX SPV Power | 36/60/72 Cell |
Switching Element | IGBT Module |
---|---|
Controller | DSP |
Efficiency | > 95% |
Battery Charging Stages | 5 (Softstart, Boost, Absorbtion, Float, Equalise) |
Low Cut Off | Volts | 10.5 / Battery +/-2% |
---|---|---|
Low Cut Off Recovery | Volts | 11.5 / Battery +/-2% |
Low Buzzer | Volts | 10.7 / Battery +/-2% |
High Cut Off | Volts | 15.5 / Battery +/-2% |
High Cut Off Recovery | Volts | 15.0 / Battery +/-2% |
Boost Charging Volt by SPV(TUB) | Volts | 14.5 / Battery +/-2% |
Boost Charging Volt by Grid(TUB) | Volts | 14.0 / Battery +/-2% |
Charging Current by Grid | Volts | 10A +/-2% |
No Load Battery Current | Volts | 0.02 |
Output@ No load | Volts | 230 +/-2% | |||||||
---|---|---|---|---|---|---|---|---|---|
Output Frequency | Hz | 50 +/-2% | |||||||
Overload | Amps | 3.5 | 3.5 | 7 | 10.5/17.4 | 17.4/26.0 | 26.0/34.8 | 34.8 | 52.2 |
Amps | 3.5 | 3.5 | 7 | 10.5/17.4 | 17.4/26.0 | 26.0/34.8 | 34.8 | 52.2 | |
Output Low Retry | - | 1 Time | |||||||
Output Short Circuit | - | 1 Time |
No of Phase | - | 1Phase - 3Wire P,N,E |
---|---|---|
Voltage Range(Inverter Mode) | V | 100 - 280 +/-2% |
Voltage Range(UPS Mode) | V | 175 - 255 +/-2% |
Frequency Range | Hz | 45 - 55 +/-2% |
Display | Alpha-numeric | 16X2 LCD | 20X4 LCD |
---|---|---|---|
Parameters | Output(Inverter) | Voltage, Current, Power and Frequency | |
Input (Grid) | Voltage and Frequency | ||
Solar | Voltage, Current, Power and Energy (Optional) | ||
Battery | Voltage, Current | ||
Status / Faults | Inverter Status, Main Status, Charger Status, Solar Status and Battery Status/Charging Stages |
Switching Element | - | MOSFET | IGBT Module | ||||||
---|---|---|---|---|---|---|---|---|---|
Output Voltage | Volts | 230 +/-2% | |||||||
Phase | - | 1Phase-3Wire P,N,E | |||||||
Output Waveform | - | Digitally Filtered Pure Sine Wave | |||||||
Frequency | Hz | 50 +/- 2% | |||||||
Changeover (Mains to Inverter) | ms | < 10ms | |||||||
Output Power Factor | Pf | 0.8 | |||||||
Overload Retry | - | 3 Times | |||||||
Switches | - | System ON/OFF, Mode Selection:Hybrid / PCU / Smart, INV /UPS Selection | |||||||
Indication (LED) | - | Inverter On, Mains In Range, Battery Low/High, Charger On, Overload, Faults | |||||||
Alarm (audible) | - | Battery Low, Overload, Charger On, Inverter On, Solar Charger On | |||||||
Protection | - | Overload, Short Circuit Protection, Over Voltage, SPV Surge and Transient protection (MOV Varistors),Reverse Polarity of Battery, Over temperature Protection, Under Voltage and Voltage Protection | |||||||
Cooling | - | Forced Air cooling(Temp Controlled) | |||||||
Communication | - | Remote Monitoring System (Over GPRS / BLE and Wifi) or Rs232 | |||||||
Operating Temp | C | 0-50 | |||||||
Operating Humidity | % | 95 | |||||||
Protection Class | - | Ip20 | |||||||
Dimension(LXWXH) | mm | 355x330x205 | 510x460x305 | 750x500x350 | 750x500x350 | ||||
Weight | kg | 18 | 21 | 31.5 | 40 | 52 | 63 | 71 | 85 |