Core Features

CONFIGURABLE USER SETTINGS

PURE SINE WAVE

TRUE MPPT

REMOTE MONITORING loT

ADVANCED DSP TECHNOLGY

INTELLIGENT MODES

AI CHARGE SHARING

Technical Specification

Parameters Units Rating
Model ASPIRO 1KVA 1KVA 2KVA 3KVA/5KVA 5KVA/7.5KVA 7.5KVA/10KVA 10KVA 15KVA
Operating DC Voltage Volts 12 24 24 48 96 120 180 240

SPV Parameters

SPV Open Circuit Voltage Range (Min-Max) Volts 18-45 36-90 36-90 72-180 144-360 180-450 270-450 360-600
Compatible SPV Panels Volts 12 24 24 48 96 120 180 240
MAX SPV Power 36/60/72 Cell

MPPT Based Charge Controller

Switching Element IGBT Module
Controller DSP
Efficiency > 95%
Battery Charging Stages 5 (Softstart, Boost, Absorbtion, Float, Equalise)

Battery

Low Cut Off Volts 10.5 / Battery +/-2%
Low Cut Off Recovery Volts 11.5 / Battery +/-2%
Low Buzzer Volts 10.7 / Battery +/-2%
High Cut Off Volts 15.5 / Battery +/-2%
High Cut Off Recovery Volts 15.0 / Battery +/-2%
Boost Charging Volt by SPV(TUB) Volts 14.5 / Battery +/-2%
Boost Charging Volt by Grid(TUB) Volts 14.0 / Battery +/-2%
Charging Current by Grid Volts 10A +/-2%
No Load Battery Current Volts 0.02

Output

Output@ No load Volts 230 +/-2%
Output Frequency Hz 50 +/-2%
Overload Amps 3.5 3.5 7 10.5/17.4 17.4/26.0 26.0/34.8 34.8 52.2
Amps 3.5 3.5 7 10.5/17.4 17.4/26.0 26.0/34.8 34.8 52.2
Output Low Retry - 1 Time
Output Short Circuit - 1 Time

Grid

No of Phase - 1Phase - 3Wire P,N,E
Voltage Range(Inverter Mode) V 100 - 280 +/-2%
Voltage Range(UPS Mode) V 175 - 255 +/-2%
Frequency Range Hz 45 - 55 +/-2%

Display

Display Alpha-numeric 16X2 LCD 20X4 LCD
Parameters Output(Inverter) Voltage, Current, Power and Frequency
Input (Grid) Voltage and Frequency
Solar Voltage, Current, Power and Energy (Optional)
Battery Voltage, Current
Status / Faults Inverter Status, Main Status, Charger Status, Solar Status and Battery Status/Charging Stages

Inverter

Switching Element - MOSFET IGBT Module
Output Voltage Volts 230 +/-2%
Phase - 1Phase-3Wire P,N,E
Output Waveform - Digitally Filtered Pure Sine Wave
Frequency Hz 50 +/- 2%
Changeover (Mains to Inverter) ms < 10ms
Output Power Factor Pf 0.8
Overload Retry - 3 Times
Switches - System ON/OFF, Mode Selection:Hybrid / PCU / Smart, INV /UPS Selection
Indication (LED) - Inverter On, Mains In Range, Battery Low/High, Charger On, Overload, Faults
Alarm (audible) - Battery Low, Overload, Charger On, Inverter On, Solar Charger On
Protection - Overload, Short Circuit Protection, Over Voltage, SPV Surge and Transient protection (MOV Varistors),Reverse Polarity of Battery, Over temperature Protection, Under Voltage and Voltage Protection
Cooling - Forced Air cooling(Temp Controlled)
Communication - Remote Monitoring System (Over GPRS / BLE and Wifi) or Rs232
Operating Temp C 0-50
Operating Humidity % 95
Protection Class - Ip20
Dimension(LXWXH) mm 355x330x205 510x460x305 750x500x350 750x500x350
Weight kg 18 21 31.5 40 52 63 71 85
  • Upto 30% more Efficient because of rMPPT Charge Controller
  • DSP / Controller based design Pure Sine Wave
  • Maximum performance to Solar Power
  • Extensive Electronic Protection
  • Digital Display
  • User Friendly :- NLSD, Grid Charging, IT Load, GENSET
  • (Enable Display by LCD) & Operating Mode (Selectable)
  • Big Date Big Display
  • Built-in Energy Meter
  • Maximized Solar Usage through Intelligent modes.
  • 40% less panel required than other PCUs
  • RS-232 (Industrial Standard MODBUS)
  • Incorporated with Microchip and ST DSP Engines
  • Safety and Protections
  • IGBT based design and Fast Charging
  • Wide range MPPT Input
  • 6 Stage Battery Charging
  • Ideally designed for cyclic application.
  • Multiple Battery Selection
  • Sleek & Aesthetic design
  • Works as standalone Solar Inverter in case of No-Grid